Ge Mac 1200 Ecg Machine Manual



The information in this manual only applies to MAC 1200 software version 6. It does not apply to earlier software versions. Due to continuing product innovation, specifications in this manual are subject to change without notice. Listed below are GE Medical Systems Information Technologiestrademarks. View and Download GE Medical Systems MAC 1200 operator's manual online. Resting ECG Analysis System. MAC 1200 medical equipment pdf manual download.

The MAC 1200 ST digital, 12-lead electrocardiograph system offers comprehensive ECG solutions with practical features that meet the needs of hospitals, clinics, office-based practices and clinical trials. Its advanced algorithm capabilities, seam­less connectivity to the MUSE and CardioSoft Cardiology Information Systems and easy-to-use features provide the top level of quality and convenience users require.

Operating Modes:

– Automatic, 12lead simultaneous

– Manual, real-time 6-channel

– Arrhythmia, continuous monitoring with event documentation

– Stress Test (optional)

GE MAC 1200 ST Features:

  • One-touch operation for acquisition, analysis, storage and printing minimizes training.
  • Measurements, interpretation and memory are available in any combination to meet specific customer needs.
  • 4 user-definable fields for patient data entry flexibility.
  • Waveform display allows rapid assessment of ECG rhythm and signal quality.
  • Portable, lightweight design with carry handle allows the MAC 1200 ST to be easily taken wherever it’s needed.
  • Full-size paper accommodates multiple standard report formats. Optional archivist paper available for longer-term ECG storage.
  • Battery powered for added versatility.
  • KISS – electrode application systemwith device integrated suction pump (optional).
  • Stress test
    • 12-channel ST-measurements
    • Variety of different stress test procedures and creation of individual parameters
    • Automatic control of diverse bicycle ergometers and treadmills
    • Advanced configuration possibilities of stage and final report

Seamless connectivity

  • Electronic information exchange to provide clinical data anytime, anywhere.
  • All digital, all the time – MAC 1200 ST’s digitally stored and formatted data protects against data loss thatcan occur in analog format
  • Communication with MUSE/CardioSoft can help clinicians increase departmental productivity and reduce errors.MAC 1200 ST can instantly send and receive completepatient ECG data for immediate remote review or overread.Cart-to-cart communication is also featured, making your ECG data even more accessible.
  • Electrocardiograms can immediately be transmitted or received from another GE electrocardiograph, thus speeding up diagnosis and enhancing decision-making support.

The MAC 1200 ST digital, 12-lead electrocardiograph system offers comprehensive ECG solutions with practical features that meet the needs of hospitals, clinics, office-based practices and clinical trials. Its advanced algorithm capabilities, seam­less connectivity to the MUSE and CardioSoft Cardiology Information Systems and easy-to-use features provide the top level of quality and convenience users require. Operating Modes: – Automatic, 12lead simultaneous – Manual, real-time 6-channel – Arrhythmia, continuous monitoring with event documentation – Stress Test (optional)

GE MAC 1200 ST Features: One-touch operation for acquisition, analysis, storage and printing minimizes training. Measurements, interpretation and memory are available in any combination to meet specific customer needs. 4 user-definable fields for patient data entry flexibility. Waveform display allows rapid assessment of ECG rhythm and signal quality. Portable, lightweight design with carry handle allows the MAC 1200 ST to be easily taken wherever it’s needed. Full-size paper accommodates multiple standard report formats. Optional archivist paper available for longer-term ECG storage. Battery powered for added versatility. KISS – electrode application system with device integrated suction pump (optional). Stress test 12-channel ST-measurements Variety of different stress test procedures and creation of individual parameters Automatic control of diverse bicycle ergometers and treadmills Advanced configuration possibilities of stage and final report

Manufacturer: GE Solutions
Manufacturer SKU: 54C9CB8B10

GE MAC 1200 ST Specs, Manuals, Brochures

GE MAC 1200 Resting ECG System

What is an ECG System?

Electrocardiography commonly referred to as either ECG or EKG is the recording of electrical activity from the heart over a period of time. The electrical activity is recorded with electrodes that are placed on the skin. Electrodes detect little electrical changes on the skin that arise from the heart muscle’s electrophysiology pattern of depolarizing and re-polarizing during each heartbeat. This process is called a cardiology test.

The electrodes are placed on the patient’s limbs and on the surface of the chest. On a typical 12-lead ECG the overall magnitude of the heart’s electrical potential is then measured from twelve different angles. Over a period of ten seconds, the overall magnitude and directions of the heart’s electrical depolarization is captured at each moment throughout the cardiac cycle. The graph depicted by the ECG system is called an electrocardiogram.

Overview of the GE MAC 1200

The GE MAC 1200 is a digital 12-lead EKG Machine that offers comprehensive ECG solutions. The MAC 1200 offers practical features that help meet the demanding needs of hospitals, clinics, office-based practices, and clinical trials. Its advanced algorithm capabilities, seamless connectivity to the CS and MUSE Cardiology Information Systems and easy-t0-use features; provide maximum quality and convenience. Resting ECGs acquired in the 12-lead mode, and the corresponding data, can then be transmitted to a PC, CardioSys system, or to a MUSE CV system. This EKG Machine is equipped with electronic utilities that ensure artifact-free recordings. Among these are the automatic baseline adjustment and the anti-drift system (Cubic Spline and ADS).

General Use of the GE MAC 1200

Ge mac 1200 ecg machine manual instructions

In the beginning of the recording, the automatic baseline adjustment algorithm verifies the incoming signal and adjusts the baseline position accordingly. During the recording, the anti-drift system (cubic spline) continuously checks the baseline position and returns it to the normal level if required. For manual mode, the anti-drift system (cubic spline) can be enabled and disabled from the setup menu. In the 12-lead and arrhythmia modes, it is always enabled.

GE MAC 1200 Features

  • This system can be configured to meet the needs of hospitals, clinics, and office-based practices
  • Allows access to EKG data gathered throughout a provider network, assuring high quality and continuity of care
  • Comprehensive solution for EKG requirements
  • Waveform LCD display
  • Interpretive EKG
  • Full-size paper reports
  • Portable with a built-in battery
  • Measurements, interpretation, and memory available in any combination
  • Simultaneous 12-lead ECG acquisition and analysis
  • Compact, lightweight design with carrying handle
  • Field upgradability

Ge Mac 1200 Ecg Machine Manual Troubleshooting

GE MAC 1200 Specifications

Signal Processing:

  • Acquisition: 12 leads – simultaneously.
  • Signal input: Type CF according to IEC.
  • Digital sampling rate: 1000 samples/second/channel.
  • Dynamic range: Differential signals for AC voltage ±, 10mV Superimposed DC voltage (Polarization voltage) ±600mV.
  • Resolution: 5 uV.
  • Frequency response:0.04 – 150 Hz.
  • Common mode rejection:> 140 dB.
  • Input impedance: > 100 M ohms.
  • Leakage current: < 10uA.
  • Pacemaker detection sensitivity: All leads, duration 0.1 – 2.5 ms, amplitude > 5 mV.

Display:

  • Type: LCD 320 x 240 pixel, backlit, Contrast adjustable.
  • Displayed data: Selected lead group, operation mode, lead check, heart rate, AC filter, muscle her, ADS, gain, speed, name, ID, 3 ECG waveforms.

Writer:

  • Type: Thermal array print head.
  • Resolution: Vertically 8 dots/mm horizontally 25um at 25 mm/s.
  • Paper: 8.5 x 11 inch.
  • Writer speed: 5, 25, 50 mm/s.
  • Paper type: Z-fold.

Keyboard:

  • Type: Membrane keypad with tactile feedback / 46 keys.

Special Functions:

  • Anti Drift System (ADS): Automatic compensation of baseline fluctuations caused by polarization voltage fluctuations at the electrodes.
  • Baseline adjustment: ECG presentation on the averaged baseline.
  • Electrode monitoring: Audible and visual indication on the LCD of disconnected electrodes or fine break. Every single electrode is monitored.
  • Copy: In the automatic 12 lead modes, after ECG, recording, copies of the ECG can be printed.
  • Test: Automatic performance test upon power up, including verification of the signal path starting at the signal input.

Power Supply:

  • Ratings: 10 – 120 V (0.32A) / 220 – 240 V (0.16A).
  • Frequency: 49 – 65 Hz.
  • Battery type: NiCad, 18V, 1.4 Ah.
  • Battery charge time: 4 hours.

Physical Specs:

  • Width: 14.5 in. (370 mm)
  • Height: 3.7 in. (94 mm)
  • Depth: 12.6 in. (320 mm)
  • Weight: 12.4 lb. (5.6 kg) with graphics display and battery.

Ge Mac 1200 Ekg Machine Manual

Have you used this product before? What features do you like? Comment below!